Glue masquerading as a catheter: Retrieval of embolized vertebroplasty cement
Abstract
Identification of foreign body objects may be difficult based on imaging characteristics. History is essential to making a diagnosis. Cement leakage is a common complication of percutaneous vertebroplasty and the optimal management for cement embolism remains unknown. This report presents a case of a 72-year-old female with asymptomatic pulmonary cement embolism, which was partially retrieved via a percutaneous endovascular approach.